4-20mA Online Conductivity Controller for Water Monitoring
The EC-6801X conductivity controller features an ABS housing for industrial water monitoring. DAXI offers project-based OEM and ODM support.
- Isolated 4–20 mA output for connection to monitoring and control systems.
- Manual or automatic temperature compensation with adjustable compensation settings.
- High and low alarm relays with adjustable hysteresis.
- Backlit 128 × 64 dot-matrix LCD with switchable Chinese and English menus.
- ABS housing for the controller and PMMA display cover.
Online Conductivity Controller Description
DAXI supplies the 4–20 mA Online Conductivity Controller for Water Monitoring, designed for continuous conductivity measurement and control in industrial water applications. Its isolated analog output connects to monitoring systems, while adjustable high and low alarm relays support process control.
Manual or automatic temperature compensation accommodates measurement requirements. A backlit LCD with Chinese and English menus simplifies setup and operation. The ABS housing contains the instrument’s display and controls. As an instruments and sensors manufacturer, DAXI also offers OEM and ODM project discussions for customers with specific requirements.
Online Conductivity Controller Technical Specifications
| Model | EC-6801X | |
| Tested parameters | Conductivity, temperature | |
| Measure range | K=0.01 | 0.02~20 uS/cm |
| K=0.1 | 0.2~200 uS/cm | |
| K=1 | 2~2000 uS/cm | |
| K=10 | 20~20000 uS/cm | |
| Four-pole conductivity sensor | 200~200000 uS/cm (Customizable) | |
| Temperature range | 0~130℃ (Resolution 0.1℃) | |
| Accuracy | + 1% FS | |
| Stability | ±1% (FS) /24h | |
| Display Method | 128 * 64Dot matrik LCD | |
| Temperature Compensation | 0~100℃ manual/ automatic (PT1000) | |
| Working pressure | 10 Bar | |
| Medium temperature | 0-100℃ | |
| Temperature compensation element | PT1000 | |
| Operating temperature | -10℃~60℃ | |
| Storage temperature | -20℃~70℃ | |
| Digital signal output | RS485 output (customization required) | |
| Cable Length | Standard 5 meters, customizable | |
| Analog signal output | 4~20mA isolation protection output maximum loop resistance 300Ω | |
| Alarm in | One set of high and low limit alarm contacts (3A/250 V AC), normally open contact relay | |
| Thread | Default 3/4″ up and down connection | |
| Power Supply | AC 220V±10% 50Hz | |
| Power consumption | ≤3W | |
| Ambient Condition | Temperature 0~ 60℃;Humidity≤85%RH | |
| Shell Material | ABS | |
| Display screen material | PMMA | |
| Material | Stainless Steel | |
| External dimensions | 96mm×96mm×110mm(high×wide×deep) | |
| Dimension | 92×92mm(high×wide) | |
| Weight | 0.8kg | |
Request a Quote for This Conductivity Controller
Oline Conductivity Controller Applications
Industrial Process Water Monitoring: Continuous conductivity monitoring for industrial water systems, including chemical processing, metallurgy, and papermaking. Configurable alarm thresholds help operators identify conductivity values outside the set limits.
Water Supply & Treatment Monitoring: Conductivity measurement at selected points in water supply and treatment systems. Manual or automatic temperature compensation supports measurement under the specified operating conditions.
Control Panel & Monitoring System Integration: Integration into monitoring and control panels through isolated 4–20 mA output. High and low alarm relay contacts provide signals for external alarm or control circuits.
Conductivity Controller Temperature Compensation
Manual and automatic temperature compensation modes allow users to configure compensation settings for their measurement requirements. Automatic compensation uses a compatible PT1000 temperature element. The compensation mode and coefficient can be adjusted through the instrument menu.
High and Low Conductivity Alarm Settings
Configurable high and low alarm thresholds help identify conductivity readings outside the selected limits. Adjustable hysteresis provides separate relay activation and release points. Relay contacts can connect to suitable external alarm or control circuits.
Conductivity Electrode Calibration and Maintenance
Electrode cell constant settings and conductivity calibration are accessible through the instrument menu. Use appropriate standard solutions and follow the calibration procedure in the manual. Keep the electrode clean and inspect the installation when readings become unstable or inconsistent.
Online Conductivity Controller Video
Related Products
Related News